Distribution points PR series
0
Distribution points of the PR11 series are used for receiving and distributing electricity, protecting various installations with voltages up to 660 V AC with a frequency of 50 Hz from overloads and short circuit currents, as well as infrequent (up t..
Request a price
Dry power transformers TS(Z)GLO up to 10 kV
0
TS(Z)GLO transformers are three-phase power dry transformers, with forced cooling and cast insulation of the "GEAFOL" type, heat resistance class "F" (155 °С), two-winding, general purpose power from 250 to 2500 kV•A voltage up to 10 kV . Complete wi..
Request a price
Dry power transformers TS(Z)N 0.66 kV and 10 kV
0
Transformers of the TS(Z)N series are three-phase, power, dry transformers, with windings made of conductors with "NOMEX" insulation of the heat resistance class "H" (180 °C), two-winding, general-purpose power from 250 to 1600 kV•A voltage up to 10 ..
Request a price
DT436   Symmetric shielded adapter for bushing type C (630A) up to 24 kV
0
Shielded cable adapter for bushing type C (630A). T-shaped symmetric model. It is a fully pre-assembled system ready for connection. The outer housing is the same for all cable types. Thanks to internal adapters, the design is suitable for cables of ..
Request a price
DTB1242   Special shielded adapter for model DT1242 (1250A) up to 42 kV.
0
The special shielded cable adapter can only be installed on the DT1242 adapter. It is used for supplying power to the main line in emergency conditions and for splitting the current load into two lines...
Request a price
DTB624S   Special shielded adapter for model DTS62S (630A) up to 24 kV.
0
The special shielded cable adapter can only be installed on adapters of type DTS624S. It is used for supplying power to the main line in emergency conditions and for splitting the current load into two lines. The DTS624S and DTB624S adapters are part..
Request a price
DTB636   Special shielded adapter for model DTS636 (630A) up to 36 kV.
0
The shielded cable adapter can only be installed on the DTS636 adapter. DTB636 is a special shielded cable adapter because it can be used for supplying power to the main line in emergency conditions and for splitting the current load into two lines. ..
Request a price
DTS1242   Asymmetric shielded cable adapter for bushing C2 (1250A) up to 42 kV.
0
Shielded cable adapter for bushing C2 (1250A). T-shaped asymmetric compact model. It is a fully pre-assembled system ready for connection. The outer housing is the same for all cable types. Thanks to internal adapters, the design is suitable for cabl..
Request a price
DTS624S   Asymmetric shielded cable adapter for bushing C (630A) up to 24 kV.
0
Shielded cable adapter for bushing C (630A). T-shaped asymmetric compact model. It is a fully pre-assembled system ready for connection. The outer housing is the same for all cable types. Thanks to internal adapters, the design is suitable for cables..
Request a price
DTS636   Shielded asymmetric cable adapter for bushing C (630A).
0
Shielded cable adapter for bushing type C (630A). T-shaped asymmetric compact model. It is a fully pre-assembled system ready for connection. The outer housing is the same for all cable types. Thanks to internal adapters, the design is suitable for c..
Request a price
DTS636SO   Shielded cable adapters for type B switchgear (400A) up to 36 kV.
0
Shielded cable adapters for type B switchgear (400A) up to 36 kV.Shielded cable adapters for type B switchgear (400A). The model is available in T-shaped form. The shielded cable adapter is a fully pre-assembled system ready for connection. The outer..
Request a price
End couplings for multi-core cables up to 1 kV
0
The end couplings are designed for hermetic termination of multi-core power cables and for connecting such cables to electrical devices of external and internal installations or overhead power lines with a voltage of up to 1 kV.Consumers are offered ..
Request a price
End couplings for multi-core cables up to 10 kV
0
The end couplings are designed for hermetic termination of multi-core power cables and for connecting such cables to electrical devices of external and internal installations or overhead power lines with a voltage of up to 10 kV.End couplings for mul..
Request a price
End couplings for multi-core cables up to 35 kV
0
The end couplings are designed for hermetic termination of multi-core power cables and for connecting such cables to electrical devices of external and internal installations or overhead power lines with a voltage of up to 35 kV.End couplings for mul..
Request a price
End couplings for single-core cables up to 1 kV
0
End couplings of types 1KWTpON, 1KNTpON, 1KWTpO(pt), 1PKVTpON, 1PKNTpON, 1PKVNTpN, 1KVNTp, 1KVNTpN are designed for terminating single-core power cables and for connecting such cables to electrical devices of external and internal installations or ov..
Request a price
End couplings for single-core cables up to 10 kV
0
End couplings of types 10PKVTpON, 10PKNTpON, 10KWTpON, 10KNTpON are designed for hermetic termination of single-core power cables and for connecting such cables to electrical devices of external and internal installations or overhead power lines with..
Request a price
End couplings for single-core cables up to 35 kV
0
End couplings of types 35PKVTpON, 35PKNTpON, 35KVTpON, 35KNTpON are designed for hermetic termination of single-core power cables and for connecting such cables to electrical devices of external and internal installations or overhead power lines with..
Request a price
High-voltage fuse PC(n) 011-10 U3
0
High-voltage fuses of the PC(t), PC(n), PC(e), PC(e) series are designed to protect high-voltage power circuits of transformers, overhead and cable networks, alternating current of 50-60Hz frequency from overloads and short-circuit currents. Our webs..
Request a price
High-voltage fuse PC(n) 011-35 U1
0
High-voltage fuses of the PC(t), PC(n), PC(e), PC(e) series are designed to protect high-voltage power circuits of transformers, overhead and cable networks, alternating current of 50-60Hz frequency from overloads and short-circuit currents. Our webs..
Request a price
High-voltage fuse PC(t) 011-10-10-20 U1
0
High-voltage fuses of the PC(t), PC(n), PC(e), PC(e) series are designed to protect high-voltage power circuits of transformers, overhead and cable networks, alternating current of 50-60Hz frequency from overloads and short-circuit currents. Our webs..
Request a price
High-voltage fuse PC(t) 011-10-10-31,5 U3
0
High-voltage fuses of the PC(t), PC(n), PC(e), PC(e) series are designed to protect high-voltage power circuits of transformers, overhead and cable networks, alternating current of 50-60Hz frequency from overloads and short-circuit currents. Our webs..
Request a price
High-voltage fuse PC(t) 011-6-31,5-20 U3
0
High-voltage fuses of the PC(t), PC(n), PC(e), PC(e) series are designed to protect high-voltage power circuits of transformers, overhead and cable networks, alternating current of 50-60Hz frequency from overloads and short-circuit currents. Our webs..
Request a price
High-voltage fuse PC(t) 012-6-63-31,5 U3
0
High-voltage fuses of the PC(t), PC(n), PC(e), PC(e) series are designed to protect high-voltage power circuits of transformers, overhead and cable networks, alternating current of 50-60Hz frequency from overloads and short-circuit currents. Our webs..
Request a price
High-voltage fuse PC(t) 111-10-16-31,5 U1
0
High-voltage fuses of the PC(t), PC(n), PC(e), PC(e) series are designed to protect high-voltage power circuits of transformers, overhead and cable networks, alternating current of 50-60Hz frequency from overloads and short-circuit currents. Our webs..
Request a price