Power transformers dry TSZGL up to 10 kV

Reviews:
(0)
  • Brand: Україна
  • Product Code: тс(з)гл
  • Availability: In Stock
Payment

We accept payment online

Delivery Information

Same day when ordering before 16:00

Quality guarantee

All products are certified

  • Product overview
  • Information
  • Reviews (0)
  • Questions (0)

TS(Z)GL are three-phase and dry power transformers with molded insulation of the "GEAFOL" type, heat resistance class "F" (155 °С), two-winding, general purpose power transformers from 100 to 2500 kV•A with a voltage of up to 10 kV. The transformers are completed with SIEMENS windings. They are used in various industries, designed for the conversion of electrical energy in three-phase alternating current electrical networks with a frequency of 50 Hz. They are installed in industrial premises and public buildings, which are subject to increased requirements in terms of fire safety, explosion protection, and environmental cleanliness.

Structure of conventional notation TSZGL-X / 10 U3

T - three-phase transformer;

S - natural air cooling;

Z - protected implementation;

GL - windings with molded insulation of the "GEAFOL" type; X - nominal power, kVA;

UZ - climatic performance and accommodation category according to DSTU 15150-69.

Specifications

Power transformers of the TS(Z)HL type with capacity from 100 to 2500 kVA with nominal voltages of the primary winding (high voltage) up to 10 kV inclusive and the secondary winding (low voltage) - 0.4 kV. The main schemes and groups of connection of windings (HV/LV) – D/un-11, U/un-0. Voltage regulation ±2x2.5%, steps of 2.5% from the nominal voltage, switching without excitation (PBZ) using jumpers.

Terms of use

- ambient temperature: from -25 °C to +40 °C;

- relative air humidity - no more than 80% at a temperature of +25 °C;

- installation height above sea level - up to 1000 m;

- environment - non-explosive, not containing conductive dust;

- for seismic impact - up to 9 points on the MSK-64 scale;

- according to the class of resistance to environmental influences: E2;

- according to the class of climatic conditions: C2;

- according to fire hazard class: F1.

Construction of transformers

Transformers consist of the following basic assembly units:

- magnetic circuit;

- windings placed on the magnetic circuit;

- taps, inlets, LV and HV buses;

- protective cover;

- forced cooling system.

The magnet wire is made of high-quality electrical steel. Special slotting on the "GEORG" line and charging of the magnetic conductor according to the "Step-Lap" scheme. Assembly of the magnetic circuit is carried out with the use of bandages, fastening pins and special glues that ensure low idle losses and noise level. To protect against corrosion, silicon-organic paints are used. LV and HV windings are made of aluminum or copper tape. In these transformers, winding insulation of the GEOFOL type is used, which consists of a compound of epoxy resin and quartz filler poured under vacuum. Modern technology of filling under vacuum and baking in electric ovens according to a temperature program guarantees high quality of windings and resistance to short-circuit currents. Transformers are manufactured with the degree of protection IROO, IR21 and IRZ1.

Transformers with casing, at the request of the customer, are manufactured in the following versions:

- with cable entries through the bottom of the transformer;

- with terminals on the transformer cover;

- with outputs on the narrow side of the transformer, left or right version.

The protective casing of the transformer provides protection of the personnel from electric shock. Access for maintenance of the transformer and the active part is provided through removable panels on the wide side of the transformer. At the request of the customer, the manufacturing plant designs and manufactures transformers of individual design or with parameters that differ from the standard ones.

Delivery completeness

The delivery set includes: transformer, thermal relay TR-100 with temperature sensors Pt1ОО, movable rollers (rollers), technical documentation (passport, technical description and instructions for storage, installation and operation). At the request of the customer, it is possible to equip the transformer with vibration mounts and flexible connections.

Overload capacity of transformers

Transformer overload is limited only by overheating of the windings. The maximum temperature exceedance of 1OO 0С for insulation class "F" is achieved under the condition: the ambient temperature is 40 °С and the operation of the transformer for a long time at the nominal load. If the ambient temperature is below 40 °C, and the previous load is less than 100% of the nominal, then the winding temperatures will be below the permissible maximum. This temperature difference can be used for short-term overloading of the transformer. The duration of a possible overload is shown in the following graphs as a function of the previous load and the magnitude of the overload. Exceeding the permissible temperature causes an alarm signal by the temperature control system, or a signal to disconnect the transformer if the transformer is overloaded for longer than the permissible time. Meet the standards MEK-76, DSTU 3076 95 (GOST 30297-95), TU U3.49-00213440-059-2002, production is certified according to ISO 9001: 2008