0.00 грн.
Checkout- Brand: Україна
- Product Code: ТОЛ-12В
- Availability: In Stock
We accept payment online
Same day when ordering before 16:00
All products are certified
- Product overview
- Information
- Reviews (0)
Transformers of reference type TOL-12-B1 and TOL-12-B2, manufactured for installation in complete distribution devices and used for signal transmission of measurement information of measuring devices and protection, automation and control devices in alternating current installations for a voltage class of up to 12 kV with a frequency of 50 Hz.
Transformers meet the standards of DSTU EN 61869-1:2017, DSTU EN 61869-2:2017 and during operation are subject to verification with an interverification interval of no more than 4 years, the initial verification is carried out in accordance with DSTU 6097:2009.
The transformers are made for internal installation and correspond to the type of climatic performance U and placement category 2 according to GOST 15150. In accordance with DSTU EN 61869-1:2017, DSTU EN 61869-2:2017, the category of transformers according to the ambient air temperature is "-40/40" .
Distinctive features of TOL-12-B1
Reduced weight and dimensions, compared to similar products of other manufacturers.
The possibility of installing the transformer in any position in space.
Absence of air sinks inside the compound.
The accuracy class of the transformer does not change during the entire service life.
Convenience and ease of installation of the transformer.
The possibility of sealing the secondary terminals of the transformer.
Insulation based on an epoxy compound provides high electrical strength, insulating and physical-mechanical properties of the product, being at the same time its supporting structure, makes the transformer completely airtight, also increases the reliability of the product and reduces to a minimum the amount of preventive work during its operation, while reducing the weight and dimensions of the product itself.
The construction with insulation from an epoxy compound ensures high fire and environmental safety.
Main technical characteristics of TOL-12-B1:
Maximum operating voltage and insulation class: 12/42/70 kV
Nominal AC frequency: 50.60 Hz
Rated primary current: 10, 15, 20, 30, 40, 50, 75, 100, 150, 200, 300, 400, 500, 600, 750, 800, 1000 A
Nominal secondary current: 5 A
Number of secondary windings: 2
Accuracy class:
-secondary winding for measurement: 0.5; 0.5S; 0.2; 0.2S;
-secondary winding for protection: 5P; 10P
Nominal secondary load:
-secondary winding for measurement at cos =0.8: 10VA
-secondary winding for protection at cos =0.8: 15VA
Overall dimensions in mm: 230-225-140
Weight: 12.4 kg
Distinctive features of TOL-12-B2:
Correspondence of overall and connecting dimensions with earlier transformers of other manufacturers.
The value of thermal and electrodynamic resistance currents has been increased compared to TOL-12-B1.
The possibility of installing the transformer in any position in space.
Absence of air sinks inside the compound.
The accuracy class of the transformer does not change during the service life.
Convenience and ease of installation of the transformer.
The possibility of sealing the secondary terminals of the transformer.
Insulation based on an epoxy compound provides high electrical strength, insulating and physical-mechanical properties of the product, being at the same time its supporting structure, completely seals the transformer, also increases the reliability of the product and reduces to a minimum the amount of preventive work during its operation, while reducing weight and dimensions . the product itself. The construction with insulation from an epoxy compound ensures high fire and environmental safety.
Main technical characteristics:
Maximum operating voltage and insulation class: 12/42/70 kV
Nominal AC frequency: 50.60 Hz
Rated primary current: 10, 15, 20, 30, 40, 50, 75, 100, 150, 200, 300, 400, 500, 600, 750, 800, 1000 A
Nominal secondary current: 5 A
Number of secondary windings: 2, 3
Accuracy class:
- secondary winding for measurement: 0.5; 0.5S; 0.2; 0.2S;
- secondary winding for protection: 5P; 10P
Nominal secondary load:
- secondary winding for measurement at cos =0.8: 10VA
- secondary protection winding at cos =0.8: 15VA
Overall dimensions in mm: 335-215-150
Weight: 20 kg
There are no reviews for this product.
No questions about this product, be the first and ask your question.